- OBJECTIVE
To lay down the procedure for replacement of cartridge filter.
- SCOPE
This SOP is applicable in water system for replacement of cartridge filter.
- RESPONSIBILITY
Water system operators/ Engineers | : | To follow the procedure |
- ACCOUNTABILITY
Head Engineering : System Compliance
- PROCEDURE
- Check the initial reading of cartridge filter & record.
- Check the initial pressure differential across the cartridge filter, it should be less than 0.5 Kg/cm2. Record the detail.
- .Pressure differential across the cartridge filter increase due to fine suspended solid that passes multi grade sand filter in the water are entrapped in it.
- If the pressure differential crosses the limit than replace the filter.
- Frequency: when the Pressure differential across the cartridge filter reach above 0.5 Kg/cm2 or at least once in a three month.
TRAINING
Trainer : Head – Quality Assurance& Engineering Department.
Trainees : Engineering- Executive & Supervisors.
- DISTRIBUTION
Master Copy : Quality Assurance Department
Controlled Copy : Engineering Department
Display Copy : Engineering Department (If Required)
ATTACHMENTS
Sr. No. | Annexure No. | Title | Format No. |
1 | NA | NA | NA |
- REFERENCES
In-house
ABBREVIATION
Abbreviation | Extended Form |
EG | Engineering |
SOP | Standard Operating Procedure |
QA | Quality Assurance |
WH | Warehouse |
NA | Not Applicable |
MB | Microbiology |
REVISION HISTORY OF CHANGE
Sr. No. | Date | Revision Details | Revision No. |